Products and solutions

Anticorrosive systems for steel-pipe interiors and concrete facilities

Paint VoyagerReference ID 1-012Corrosion protection and lining

Related keywords

Corrosion protection and liningPaint Voyager

Overview / Summary Note

Provide corrosion protection suited separately to steel pipes and concrete.

This category groups vinyl ester resin glass-flake coatings for steel-pipe interiors and anticorrosive coatings and linings for concrete facilities. Select them as separate coating and surface preparation systems according to contact conditions with water or chemical solutions and differences in substrate.

COATING / PRODUCTS & SOLUTIONS
Illustrative concept diagram · Illustration of coating film and substrate classifications
This is not a photograph, dimensional drawing or performance dataset for an actual product.

When to consider it

Consider these when protecting the interiors of water conveyance pipes or drainage-related equipment, or suppressing corrosion and deterioration of concrete facilities.

Rust on steel and defects or moisture in concrete require different treatment. Start by defining the substrate condition, rather than assuming that applying the same coating will address both.

Main applications and requirements

  • Steel-pipe interiors in contact with seawater, circulating water, and similar liquids
  • Concrete facilities in contact with chemical solutions or wastewater
  • Selecting anticorrosive coatings and linings suited to substrate and contents

Characteristics and mechanisms

01

Lengthen the penetration path with glass flakes

The product family for steel pipes is designed to limit ingress of environmental substances through a film containing flake-shaped glass.

02

Prepare the surface for each substrate

Check steel surface preparation separately from concrete repair and moisture management.

03

Evaluate liquid contact

Consider systems suited to the chemical solution, temperature, flow, and abrasion conditions.

Basic information and general technical explanation

Film continuity and the substrate are important for linings

If a protective layer in contact with liquid has pinholes or defects at edges, deterioration may progress locally. Check continuity, adhesion, curing, and post-application inspection as well as film thickness.

For concrete, moisture content, cracks, and weak surface layers affect the coating film. Do not transfer a steel-pipe specification; select a substrate-specific combination of repair, primer, and lining.

Checks for selection and introduction

Define the substrate and contacting liquid, then check application, inspection, and curing through to service.

Conditions to check when selecting

  • Steel or concrete substrate, and extent of substrate deterioration
  • Liquid type, concentration, temperature, flow velocity, and cleaning conditions
  • Repair, film thickness, defect inspection, and curing period before service

Support from CoatureVietnam

Please share the facility, substrate condition, and conditions of the contacting liquid. Consultation can begin by sharing the conditions and organizing the documents and evaluation items needed to assess suitability. The scope of support for testing, implementation, and supply is confirmed individually.

Related resources, Helpful Information and FAQ

Related Helpful Information

Chemical-resistant paints

Introduces chemical effects on coating films and considerations when selecting resins and applications.

Why apply paint in multiple layers?

Introduces the roles of primers and topcoats and their combination within the complete coating system.

Related trouble prevention and remedies

Process and application relevance06-004

Why rust can occur even with rust-preventive coatings

Why read this: To review the substrate, surface preparation, film thickness and service environment as well as the anti-corrosion paint.

Process and application relevance06-003

Reading the Cause from the Pattern of Rust

Why read this: To identify factors requiring investigation from the appearance and location of the rust.

Process and application relevance11-013

Do not judge corrosion-protection coating by initial price alone: Recoating intervals and life-cycle cost

Why read this: To consider corrosion-protection specifications and recoating intervals from a maintenance perspective.

Condition to check: When considering long-term corrosion-protection and maintenance plans

Common consultation questions

Are the specifications for steel pipes and concrete the same?

They are separate specifications. Check suitability for each substrate because adhesion, moisture content, repair methods, and other factors differ.

Consultation and inquiries

Please share the facility, substrate condition, and conditions of the contacting liquid. You are welcome to consult us using whatever information is currently available.

Information to prepare

  • Conditions to confirm: the facility, substrate condition, and conditions of the contacting liquid
  • Current conditions and issues observed
  • Desired finish or improvement

When contacting us, please quote Reference ID: 1-012

Prepare a consultation message

Copy the text below, add your on-site situation and send it to us via the Contact page.

Let's clarify where to start checking.

You can summarize the situation on site and what you want to confirm even before choosing a product.