Products and solutions

Waterborne heavy-duty anticorrosive coating systems

Paint VoyagerReference ID 1-011Anticorrosive coatings

Related keywords

Anticorrosive coatingsPaint Voyager

Overview / Summary Note

Consider waterborne options from primer to topcoat.

Heavy-duty anticorrosive systems combining a waterborne zinc-rich primer, epoxy primers and intermediate coats, and polyurethane or fluoropolymer topcoats. Consider each layer and the drying process together, rather than simply replacing a single coating with a waterborne product.

COATING / PRODUCTS & SOLUTIONS
Illustrative concept diagram · Illustration of coating film and substrate classifications
This is not a photograph, dimensional drawing or performance dataset for an actual product.

When to consider it

Consider these when reducing solvent use or addressing odor while maintaining corrosion protection.

Humidity, ventilation, and recoating times affect the process, so check whether work can proceed under the same drying conditions as the current solvent-based specification.

Main applications and requirements

  • Waterborne heavy-duty anticorrosive coating of bridge and industrial-plant exteriors
  • Addressing odor in neighboring areas and the workplace
  • Reviewing coating systems and drying processes for new construction and refurbishment

Characteristics and mechanisms

01

Combine waterborne materials for each layer

Build the system using the specified material combination, from the anticorrosive layer next to the steel through to the finish.

02

Select the finishing resin

Consider polyurethane or fluoropolymer topcoats according to the required weather resistance.

03

Manage water evaporation within the process

Check humidity and ventilation as well as temperature, and determine when the coating is ready for the next process.

Basic information and general technical explanation

Moving to waterborne coatings changes materials and drying management

Waterborne coatings form films under conditions involving water evaporation and resin curing. High humidity, condensation, or inadequate ventilation may delay drying, so the application and curing environment must be prepared.

Evaluate corrosion protection using the specified primer, intermediate coat, topcoat, surface preparation, and film thickness. The classification “waterborne” alone cannot establish suitability for every service environment or determine safety.

Checks for selection and introduction

Check the material combination and drying conditions, then evaluate suitability in the current process.

Conditions to check when selecting

  • Corrosive environment and new construction or refurbishment
  • Materials, film thickness, and recoating intervals for each layer
  • Temperature, humidity, ventilation, and protective measures against rain and condensation

Support from CoatureVietnam

Please share the current coating system, application environment, and improvements sought by moving to waterborne coatings. Consultation can begin by sharing the conditions and organizing the documents and evaluation items needed to assess suitability. The scope of support for testing, implementation, and supply is confirmed individually.

Related resources, Helpful Information and FAQ

Related Helpful Information

Why apply paint in multiple layers?

Introduces the roles of primers and topcoats and their combination within the complete coating system.

Adhesion and causes of peeling

Introduces adhesion to the substrate, moisture at the interface and stresses within a coating film.

Related trouble prevention and remedies

Process and application relevance06-004

Why rust can occur even with rust-preventive coatings

Why read this: To review the substrate, surface preparation, film thickness and service environment as well as the anti-corrosion paint.

Process and application relevance06-003

Reading the Cause from the Pattern of Rust

Why read this: To identify factors requiring investigation from the appearance and location of the rust.

Process and application relevance11-013

Do not judge corrosion-protection coating by initial price alone: Recoating intervals and life-cycle cost

Why read this: To consider corrosion-protection specifications and recoating intervals from a maintenance perspective.

Condition to check: When considering long-term corrosion-protection and maintenance plans

Common consultation questions

Can only part of an existing specification be changed to waterborne?

Check intercoat compatibility. Even for a partial change, evaluate the specification including compatibility with the existing coating and other layers, and drying conditions.

Consultation and inquiries

Please share the current coating system, application environment, and improvements sought by moving to waterborne coatings. You are welcome to consult us using whatever information is currently available.

Information to prepare

  • Conditions to confirm: the current coating system, application environment, and improvements sought by moving to waterborne coatings
  • Current conditions and issues observed
  • Desired finish or improvement

When contacting us, please quote Reference ID: 1-011

Prepare a consultation message

Copy the text below, add your on-site situation and send it to us via the Contact page.

Let's clarify where to start checking.

You can summarize the situation on site and what you want to confirm even before choosing a product.