Products and solutions

Heat-resistant coatings for corrosion under insulation

Paint VoyagerReference ID 1-009Heat-resistant coatings

Related keywords

Heat-resistant coatingsPaint Voyager

Overview / Summary Note

Address corrosion beneath insulation, even where it cannot be seen.

Heat-resistant coatings selected to suppress corrosion occurring beneath insulation. Used on the exterior of insulated piping and tanks, they are evaluated not only for operating temperature but also for temperature changes during shutdown and startup and wet conditions within the insulation.

COATING / PRODUCTS & SOLUTIONS
Illustrative concept diagram · Illustration of coating film and substrate classifications
This is not a photograph, dimensional drawing or performance dataset for an actual product.

When to consider it

Consider these when corrosion is found after removing insulation, or when condensation during equipment shutdown or rainwater ingress is a concern.

Do not assess them in the same way as ordinary heat-resistant coatings; define the conditions of the insulation, cladding, drainage, and inspection together.

Main applications and requirements

  • Insulated piping and tank exteriors in industrial plants
  • Maintenance measures against corrosion under insulation
  • Coating equipment exteriors subject to temperature cycling and wet conditions

Characteristics and mechanisms

01

Address the environment beneath insulation

Consider these as corrosion-control measures for areas where moisture enters and drying becomes difficult.

02

Select with temperature changes in mind

Check changes in heat and moisture during shutdown and startup as well as during continuous operation.

03

Coordinate with the insulation structure

Consider measures including cladding integrity, drainage, and inspection methods in addition to coating.

Basic information and general technical explanation

CUI: corrosion progressing beneath insulation

CUI is corrosion that progresses on equipment exteriors due to moisture and other substances entering the insulation. Because insulation covers the surface, a characteristic difficulty is that changes cannot readily be identified by visual inspection from outside.

Do not decide suitability solely by the coating's heat-resistance temperature; check material, surface treatment, wet conditions, and temperature cycling. Treat assessment of equipment that is already corroded separately from protection through coating.

Checks for selection and introduction

Define conditions during operation and shutdown and the insulation structure, then check the specification to adopt.

Conditions to check when selecting

  • Substrate, extent of corrosion, and surface preparation
  • Operating temperature, temperature changes during shutdown, and wetting conditions
  • Insulation, cladding, and drainage structures, and inspection plan

Support from CoatureVietnam

Please share the equipment, temperatures during operation and shutdown, and condition of the insulation. Consultation can begin by sharing the conditions and organizing the documents and evaluation items needed to assess suitability. The scope of support for testing, implementation, and supply is confirmed individually.

Related resources, Helpful Information and FAQ

Related Helpful Information

Heat-resistant paints

Introduces paints for exposure to high temperatures and differences between resin systems.

Characteristics and uses of silicone resins

Introduces the structure of silicone resins and their use in heat-resistant and weather-resistant applications.

Related trouble prevention and remedies

Process and application relevance08-016

Cracking Arises from Differences in Expansion and Contraction Between the Substrate and Coating Film

Why read this: To examine differences in expansion and contraction between the substrate and coating film as temperature changes.

Process and application relevance02-009

How to Read Test Data Correctly: Specification Values Alone Cannot Resolve Shop-Floor Problems

Why read this: To clarify differences between service temperature, holding time and environment and the test conditions.

Process and application relevance02-003

Paints That Dry and Paints That Harden by Reaction: The Difference Between Drying and Curing

Why read this: To check the drying and curing conditions needed for coating film formation.

Condition to check: Confirm actual curing conditions in the technical documentation for the product concerned

Common consultation questions

Can any heat-resistant coating be used beneath insulation?

Heat resistance alone is not enough to decide. Check whether the specification addresses moisture and temperature cycling beneath insulation.

Consultation and inquiries

Please share the equipment, temperatures during operation and shutdown, and condition of the insulation. You are welcome to consult us using whatever information is currently available.

Information to prepare

  • Conditions to confirm: the equipment, temperatures during operation and shutdown, and condition of the insulation
  • Current conditions and issues observed
  • Desired finish or improvement

When contacting us, please quote Reference ID: 1-009

Prepare a consultation message

Copy the text below, add your on-site situation and send it to us via the Contact page.

Let's clarify where to start checking.

You can summarize the situation on site and what you want to confirm even before choosing a product.