Products and solutions

Zinc-rich primers and high-build zinc-rich paints

Paint VoyagerReference ID 1-003Zinc-dust coatings

Related keywords

Zinc-dust coatingsPaint Voyager

Overview / Summary Note

Use the action of zinc for corrosion protection throughout the coating system.

A group of anticorrosive primers containing a high proportion of zinc dust. Inorganic types and organic types using epoxy resin have different curing mechanisms and application conditions. For corrosion protection of steel structures, consider surface preparation, intermediate coats, and topcoats as a single coating specification.

COATING / PRODUCTS & SOLUTIONS
Illustrative concept diagram · Illustration of coating film and substrate classifications
This is not a photograph, dimensional drawing or performance dataset for an actual product.

When to consider it

Consider these when protecting steel in harsh corrosive environments such as bridges and industrial plants.

The surface preparation achievable and the condition of existing coatings differ between new construction and repair. Define the required corrosion protection and site application conditions, then distinguish between organic and inorganic types, and standard and high-build types.

Main applications and requirements

  • Primers for heavy-duty corrosion protection of steel structures
  • Considering anticorrosive coating specifications for new construction and refurbishment
  • Protecting steel in combination with intermediate coats and topcoats

Characteristics and mechanisms

01

Corrosion protection with zinc dust

The coating film uses the anticorrosive action arising from electrical contact between zinc and steel.

02

Distinguish organic and inorganic types

Resin-based and inorganic types differ in curing conditions and handling and cannot be grouped under the same application conditions.

03

Design through to subsequent coating layers

Check the combination with the specified intermediate coat and topcoat according to surface condition and porosity.

Basic information and general technical explanation

Zinc-dust content alone does not determine corrosion protection

For zinc to protect steel, contact between the zinc particles and with the steel is important. Intervening rust or existing coating may prevent this action from being fully achieved.

Some inorganic types depend on ambient humidity for curing, while organic types require management of the reaction between the base component and curing agent. Evaluate application performance within the specified coating system, including bubbles and pinholes during overcoating.

Checks for selection and introduction

Select the type from the required coating specification and the surface preparation that can be performed.

Conditions to check when selecting

  • New construction or repair, and the condition of the existing coating and steel surface
  • Organic or inorganic type, curing conditions, and film thickness
  • Specified overcoating method and application environment

Support from CoatureVietnam

Please share the corrosive environment, surface preparation method, and planned coating specification. Consultation can begin by sharing the conditions and organizing the documents and evaluation items needed to assess suitability. The scope of support for testing, implementation, and supply is confirmed individually.

Related resources, Helpful Information and FAQ

Related Helpful Information

Why apply paint in multiple layers?

Introduces the roles of primers and topcoats and their combination within the complete coating system.

Related trouble prevention and remedies

Process and application relevance06-004

Why rust can occur even with rust-preventive coatings

Why read this: To review the substrate, surface preparation, film thickness and service environment as well as the anti-corrosion paint.

Process and application relevance06-003

Reading the Cause from the Pattern of Rust

Why read this: To identify factors requiring investigation from the appearance and location of the rust.

Process and application relevance11-013

Do not judge corrosion-protection coating by initial price alone: Recoating intervals and life-cycle cost

Why read this: To consider corrosion-protection specifications and recoating intervals from a maintenance perspective.

Condition to check: When considering long-term corrosion-protection and maintenance plans

Common consultation questions

Can any topcoat be used over a zinc-rich coating?

The specified combination must be checked. Whether direct overcoating is possible or an intermediate coat is needed depends on the primer type and topcoat.

Consultation and inquiries

Please share the corrosive environment, surface preparation method, and planned coating specification. You are welcome to consult us using whatever information is currently available.

Information to prepare

  • Conditions to confirm: the corrosive environment, surface preparation method, and planned coating specification
  • Current conditions and issues observed
  • Desired finish or improvement

When contacting us, please quote Reference ID: 1-003

Prepare a consultation message

Copy the text below, add your on-site situation and send it to us via the Contact page.

Let's clarify where to start checking.

You can summarize the situation on site and what you want to confirm even before choosing a product.